MGPS · Design to service

Medical gas pipeline systems for hospitals in Tamil Nadu

We plan, supply, install, test, commission and maintain medical gas pipelines for oxygen, medical air, vacuum, nitrous oxide and carbon dioxide, for a 10-bed nursing home or a multi-speciality hospital.

Copper medical gas pipeline with pressure regulators and air dryer installed by SSA
What is MGPS

One network instead of cylinders in every ward

A medical gas pipeline system takes gas from a central source (a cylinder manifold, an oxygen plant, a compressor or a vacuum pump) and carries it through copper pipe to outlets at every bed, theatre and ICU.

  • Safer wards: no heavy cylinders moved between patients, no risk of the wrong gas at the bed.
  • Supply that does not break: automatic changeover between cylinder banks with alarms before pressure drops.
  • Control in an emergency: area valve boxes isolate one zone while the rest of the hospital stays on gas.
  • Lower running cost: less gas wasted, less cylinder handling, easier to expand.
MGPS overview: cylinder bank feeding colour-coded oxygen, vacuum, air, nitrous oxide, CO2 and nitrogen outlets
Gases we pipe

Six services, each with its own colour and outlet

Every gas has a colour-coded outlet and a gas-specific probe, so equipment can only connect to the right supply.

Oxygen (O₂)Wards, ICU, theatres, emergency
Medical Air (AIR)Ventilators, nebulisers, anaesthesia
Vacuum (VAC)Suction in wards and theatres
Nitrous Oxide (N₂O)Anaesthesia and analgesia
Carbon Dioxide (CO₂)Laparoscopic surgery
Nitrogen (N₂)Powering surgical tools
How we work

Design, supply, installation, testing, commissioning, service

One team carries the project from the first site visit to maintenance years later.

  1. Design

    Site survey, bed count and gas demand worked out, then a pipeline and manifold layout drawn for your building.

  2. Supply

    Copper pipe, outlets, valves, alarms, manifolds and plant sourced to the agreed layout and gas standard.

  3. Installation

    Pipes laid, brazed, clamped and labelled; outlets, bed head panels, valve boxes and alarms fitted.

  4. Testing

    Pressure and leak tests, cross-connection checks and flow checks at every outlet before any patient uses it.

  5. Commissioning

    The system brought into service, alarms set, and your staff shown how to run and isolate it.

  6. Service

    Maintenance, repairs, extensions and spares after handover, so the supply stays safe for years.

MGPS components · 01

Medical Gas Outlets

Colour-coded outlets put each gas at the bedside without risk of a wrong connection. We supply AMICO, BS, DIN and AGSS types, surface-mounted or concealed in ABS and stainless-steel panels.

MGPS components · 02

Area Valve Boxes, Valves & Alarms

Area valve boxes let staff isolate one zone without shutting down the hospital, and the alarm panels watch line pressure for every gas around the clock with visual and audible warnings.

MGPS components · 03

Cylinder Manifolds & Control Panels

The manifold room is where the supply starts. Our control panels switch between cylinder banks so the oxygen supply never breaks, with alarms and an emergency reserve.

MGPS components · 04

Medical Air & Vacuum Plants

Clean, dry medical air and dependable central suction for wards and theatres: compressors, receivers, dryers, filtration and vacuum pumps, installed and piped to every outlet.

MGPS components · 05

Copper Pipes, Fittings & Tubing

The pipeline itself: copper pipe and fittings, high-pressure colour-coded tube, NIST connectors and nylon hose, laid, brazed, labelled and pressure-tested.

Applications

Where hospitals use medical gas

  • Wards and private rooms: oxygen, air and suction at every bed head panel.
  • ICUs and HDUs: multiple outlets per bed, alarms at the nurses’ station.
  • Operation theatres: concealed outlet panels, N₂O, CO₂, AGSS and theatre suction.
  • Emergency, labour and recovery rooms: oxygen and suction ready at all times.
  • Plant rooms: cylinder manifolds, oxygen plants, medical air and vacuum.
Theatre corridor with colour-coded medical gas pipelines and isolation valves
Questions

MGPS questions we are often asked

What is a medical gas pipeline system (MGPS)?

An MGPS carries medical gases such as oxygen, medical air, nitrous oxide and carbon dioxide, along with vacuum for suction, from a central source (cylinder manifolds, an oxygen plant or compressors) through a copper pipeline to outlets at each bed, theatre and ICU. It replaces moving cylinders around the wards.

Which gases can SSA pipe in my hospital?

We install pipelines and outlets for oxygen, medical air, vacuum (suction), nitrous oxide, carbon dioxide and nitrogen, with anaesthetic gas scavenging (AGSS) outlets for theatres.

Do you install MGPS outside Namakkal?

Yes. Our head office is in Konur, Namakkal, with branches in Chennai, Vellore, Coimbatore, Madurai and Hosur. We work across Tamil Nadu and also take projects in Puducherry, Karnataka and Hyderabad / Telangana.

Can you extend or repair an existing pipeline?

Yes. We add outlets and beds to existing systems, replace faulty outlets, valves and alarms, upgrade manual manifolds to automatic, and carry out leak testing and maintenance.

What is the difference between automatic and semi-automatic manifolds?

Both feed the pipeline from two banks of cylinders. A semi-automatic panel needs staff to switch banks by hand when one runs low; an automatic panel changes over by itself, keeps the pressure steady and raises an alarm (and, on our fully automatic panel, an SMS alert) so the supply never breaks.

How do I get a quotation?

Call or WhatsApp us, or send the enquiry form with the number of beds, the gases you need and your location. We will discuss the site, visit if needed, and send a quotation.

One call gets your hospital’s oxygen flowing.

Site survey, layout, supply, installation, testing and commissioning, and service after handover. Call +91 86950 94933 or send an enquiry.